Unmarketed Labs
Studio concept

Paali

Shop-floor tabletLive OEETwo-tap downtimeChakan press shop

A tablet for the press shop floor: one tile per line, OEE that tells the truth, and the reason for a stop logged in two taps with gloves on.

Studio concept · not a client project

A studio concept: a fictional product we designed and built to show how we work. Not a client project.

Custom softwareIndustrial UITabletBrandPrototype
Line 3 stops. Tap the tile, tap the reason. Maintenance is paged before the supervisor has put the tablet down.Tablet · Downtime

Downtime that is not written down did not happen.

Paali is a product we invented for a press shop in Chakan: Indrayani Pressworks, Plant 2, Bay C. Six lines, from an 800 tonne transfer press to a roller hem cell, making brackets, rails and control arms for car makers. Shift B runs from two in the afternoon to half past ten.

When a line stops, the reason usually goes on a paper sheet at the end of the shift, from memory. So the plant's numbers look better than the floor feels, and nobody knows which stops to fix first. Paali puts the reason on the line tile, at the moment it stops, in two taps. The PLC already knows the fault code, so the likely reason is suggested and the right team is paged as soon as it is picked.

We designed the brand and the tablet for gloves, glare and arm's length, and built it as a working prototype with a live OEE model. The plant, the people and the figures are fictional.

What it had to do
  1. 01

    Show every line's state across the bay, readable from two metres away.

  2. 02

    Turn a stopped line into the loudest thing on the screen, and only that.

  3. 03

    Log the reason in two taps, with the PLC's best guess first.

  4. 04

    Keep OEE honest: a stop costs points, and the number does not bounce back.

Line 3 stops at 16:41. Two taps.

The prototype's own model, rebuilt: every number comes from each line's shift timeline, and OEE is availability times performance times quality, worked out live. Time runs ten times faster here. Tap the red tile, then tap a reason.

paali
Indrayani Pressworks
Chakan Plant 2 · Press shop · Bay C
Shift B14:00 to 22:30
PLC link · 6 of 6
16:41

Lines

6 lines · 4 running · 1 changeover · 1 idle

L1800T Transfer6-station transferRun
0%
OEE · shift
A0
P0
Q0
CM-2207 Front cross member9.0 s
0/ 0 plan0
14:0018:0022:30
L1Stopped
00:00
PLC E-214 · main motor overload, press 2
OEE 0
L1Down · logged
00:00
PF-01Press fault
Maintenance paged: Sanjay Pawar, on the way
LoggedOEE 0
L2400T ProgressiveCoil fed · 1.6 mmRun
0%
OEE · shift
A0
P0
Q0
BRK-4471 Seat rail bracket LH2.4 s
0/ 0 plan0
14:0018:0022:30
L2Stopped
00:00
PLC E-214 · main motor overload, press 2
OEE 0
L2Down · logged
00:00
PF-01Press fault
Maintenance paged: Sanjay Pawar, on the way
LoggedOEE 0
L3630T Tandem4 presses · robotsRun
0%
OEE · shift
A0
P0
Q0
LCA-1180 Lower control arm RH12.0 s
0/ 0 plan0
14:0018:0022:30
L3Stopped
00:00
PLC E-214 · main motor overload, press 2
OEE 0
L3Down · logged
00:00
PF-01Press fault
Maintenance paged: Sanjay Pawar, on the way
LoggedOEE 0
L4Weld cell W22 robots · spot + MIGRun
0%
OEE · shift
A0
P0
Q0
RAB-3306 Rear axle bracket assy48.0 s
0/ 0 plan0
14:0018:0022:30
L4Stopped
00:00
PLC E-214 · main motor overload, press 2
OEE 0
L4Down · logged
00:00
PF-01Press fault
Maintenance paged: Sanjay Pawar, on the way
LoggedOEE 0
L5250T ProgressiveCoil fed · 1.2 mmSMED
Die changeBTC-0918 → BTC-0920
0 of 20:00 target
Step 3 of 5 · Die in
14:0018:0022:30
L6Hem cell H1Roller hem · 1 robotIdle
No production plannedFree until the next order. Nothing to watch here.Next: DHR-5512 at 18:00
Plant OEE · this shift
0%
target 78.0
Availability0
Performance0
Quality0
Shift output0of 0 pcs
vs plan now0pcs
Downtime · Shift B
0 min
    Reason logged
    1. 0Line stops
    2. 1Tap the tile
    3. 2Tap the reason
    4. ✓Back up, OEE kept honest
    The Line 3 tile in alarm red: STOPPED, 00:21, PLC E-214 main motor overload on press 2, OEE 84.3 down 0.20 since the stop, and a white Tap to log reason button.

    Red means stopped. Nothing else is red.

    The tile turns alarm red and pulses, the timer counts up, and OEE shows what the stop has cost so far. One button: tap to log the reason.

    The reason sheet: Why did the line stop? Press fault marked PLC suggests, beside Die change, Tool breakage and Air or power.

    The PLC suggests, a person decides

    Eight reasons in tiles big enough for a gloved finger. The fault code points at a press fault, so that one is marked. One tap logs it and pages maintenance.

    Line 3 running again at 83.4 percent, labelled Back up, minus 1.2 points, with the press fault at the top of the downtime list.

    Back up, and honest about it

    When the line restarts, the tile says so and shows the points the stop cost. OEE does not jump back to where it was. The stop is in the log, with who logged it.

    Built for gloves, glare and arm's length.

    A press shop is loud, bright and full of people holding things. The tablet is mounted on a pillar and read from across the aisle, so every decision started from the floor, not from a desk.

    Gloves

    Targets the size of a thumb

    Reason tiles are 150 pixels tall on the tablet, and the button on a stopped tile is 52. Nothing needs a fingertip.

    Glare

    Concrete paper, black ink

    A light concrete ground and heavy condensed numerals stay legible under sodium lamps and daylight from the roof sheets.

    Arm's length

    Numbers you can read walking past

    OEE in 66 pixel numerals, the stop timer in 86. State is a word and a colour, never colour alone.

    Quiet by default

    Grey is normal

    Running lines are grey and calm. Colour is spent only on what needs a person: red for stopped, yellow for logged and waiting, amber for a die change.

    Concrete, graphite and safety yellow.

    Design system
    Barlow Condensed · the numbersTabular, so a ticking timer does not shake
    00:21
    Numbers and labelsBarlow Condensed
    InterfaceBarlow
    CodesIBM Plex Mono
    The markA gauge, two-thirds of the way round
    paaliA ring that fills as the shift goes on, in safety yellow.
    Down and logged: the hazard edge
    Line statesA word and a colour, every time
    Run
    Stopped
    Down · logged
    SMED
    Idle
    Quality hold
    ColourIndustrial HMI thinking: the normal state is quiet grey
    Concrete
    #E2E0DA
    Panel
    #F5F4F0
    Graphite
    #17191B
    Ink
    #111213
    Safety yellow
    #FFC20E
    Alarm red
    #D4271B
    Run green
    #17914F
    Changeover
    #DE7F0A
    Steel
    #3D5B78

    Up next

    Have something to build? We'd love to hear about it.